29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
    29 Liter Class B white autoclave with USB and integrated printer
    29 Liter Class B white autoclave with USB and integrated printer
    29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
    29 Liter Class B white autoclave with USB and integrated printer
    29 Liter Class B white autoclave with USB and integrated printer
    29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer

Product information

Description

White 29-liter Class B Autoclave with USB and Built-in Printer

Warranty Details

Safety
- Water quality must be below 20 microsiemens for the autoclave to start cycles.

- The cycle will not start if the door is not properly closed.
- The automated dual hydraulic locking safety system prevents the door from opening while the chamber is under pressure.
- Safety valves prevent pressure generator and camera failure.
- A safety thermostat prevents overheating in the chamber and generator
- An automatic safety lock prevents the door from accidentally opening during the sterilization process. The process protector automatically cuts off electrical power if there is a short circuit or if the power supply is unstable.
- A failure alarm indicates a failed cycle and provides a detailed error code.
- A door alarm indicates that the door is not secured.
- A low-water alarm indicates when the water tank is empty or overfilled.

Icanclave Autoclave: Maintenance and Error Message Guide

Technical Specifications
- Voltage: 220-240 VAC; 50/60 Hz; 10A
- External dimensions: W x H x L: 490 x 455 x 860 mm
- Tray dimensions: #1. 185x570 mm #2. 213x570 mm #3. 227x570 mm
- Circuit breaker: F16A / 400 V
- Rated power: 1500 VA
- 2300 W
- Sterilization temperature: 121 °C / 134 °C
- Distilled water tank capacity: 2.5 L
- Operating temperature: 5 °C / 40
- Relative humidity: Max. 80%, non-condensing
- Net weight: 65 kg
- Maximum noise level: <70 dB
- Atmospheric pressure: 76 kPa / 106 kPa

Product intended for the European market – 220–240 V / 50 Hz power supply – European plug (type E/F)

Icanclave Autoclave: Maintenance and Error Message Guide

Components
- Distilled water tank
- LCD screen
- Control panel
- Main switch
- Key for draining distilled and used water
- USB port
- Internal printer (allows printing of sterilization cycle reports on thermal paper after the end of the cycle.)
- Safety valve
- Ventilation grille
- Locking system
- Power cable
- Label

Included Accessories
- Sterilizer
- USB
- 3 instrument trays
- Tray support
- Handle for tray removal
- Door adjustment tool
- 2 drain hoses
- Door guide
- Instruction manual

Regulations
- 93/42 / EEC Medical devices directive.
- 97/23 / EEC Pressure equipment directive.
- EN 13060 Small steam sterilizers.
- EN 61326, EN 61000 EMC.
- EN 61010-1, UL 61010-1 safety requirements.
- EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for processing medical materials.

Autoclave Process Step-by-Step
1. Open the door, take the tools and accessories located in the sterilization chamber, remove the packaging and clean them.

2. Connect the power cord to a suitable power source.

3. Connect the printer.

4. Power on: the main switch is located on the front, at the bottom right of the device. Once turned on, the LCD screen will light up and the basic operating symbols of the sterilizer, such as door position, water level, sterilization program, date, time, will light up.

5. Remove the top cover then fill the distilled water tank. If a beep sounds, it means you have exceeded the allowed water level in the tank. Empty the excess water until the alarm stops.

6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These must not be in contact. Check that all instruments are properly placed, so that water does not remain in hollow parts. Do not overload the instrument trays and do not place them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.

7. Select the sterilization program.

8. Start the sterilization cycle.
After selecting the sterilization program, place the instruments on the trays in the chamber using the provided plastic tongs.
Once the instruments are properly placed inside, close the door. Caution: make sure the door is properly closed, otherwise the sterilizer will not be able to operate.

9. Start the sterilization program.
Press the start button, the autoclave will begin to operate for about 30-75 minutes.

10. End of the sterilization cycle.
Once the sterilization cycle is complete, the printer will automatically print the full cycle report.
Once the pressure has returned to 0, you can open the door and remove the instruments. The autoclave will alert you with a beep once the sterilization cycle is complete.
Caution: Use the plastic tongs to remove the instruments.

IMPORTANT: Do not reuse the wastewater after draining the tank.

It is important to keep the packaging box in case of after-sales service

Program

Temp.

/Pressure

Sterilization time Total time (min)
8D Pro 12D Pro

18D Pro

23D Pro
QUICK 134 134℃/210Kpa 3.5 min 10-20 11-20 12-30 15-30
PACKAGED 134 134℃/210Kpa 4 min 25-40 28-45 30-49 38-57
PACKAGED 121 121℃/110Kpa 20 min 36-46 37-48 38-54 46-62
PRION 134 134℃/210Kpa 18 min 35-46 36-48 37-52 45-60
TEST B&D 134 3.5 min 10-20 15-25 15-30 28-35
TEST HELIX 134 3.5 min 10-20 15-25 15-30 28-35
EMPTY TEST – – 17-20 18-21 19-22 20-25

* The cycle duration is based on different loads and with/without preheating.

* The sterilization time and drying time can be adjusted.

Description

White 29-liter Class B Autoclave with USB and Built-in Printer

Warranty Details

Safety
- Water quality must be below 20 microsiemens for the autoclave to start cycles.

- The cycle will not start if the door is not properly closed.
- The automated dual hydraulic locking safety system prevents the door from opening while the chamber is under pressure.
- Safety valves prevent pressure generator and camera failure.
- A safety thermostat prevents overheating in the chamber and generator
- An automatic safety lock prevents the door from accidentally opening during the sterilization process. The process protector automatically cuts off electrical power if there is a short circuit or if the power supply is unstable.
- A failure alarm indicates a failed cycle and provides a detailed error code.
- A door alarm indicates that the door is not secured.
- A low-water alarm indicates when the water tank is empty or overfilled.

Icanclave Autoclave: Maintenance and Error Message Guide

Technical Specifications
- Voltage: 220-240 VAC; 50/60 Hz; 10A
- External dimensions: W x H x L: 490 x 455 x 860 mm
- Tray dimensions: #1. 185x570 mm #2. 213x570 mm #3. 227x570 mm
- Circuit breaker: F16A / 400 V
- Rated power: 1500 VA
- 2300 W
- Sterilization temperature: 121 °C / 134 °C
- Distilled water tank capacity: 2.5 L
- Operating temperature: 5 °C / 40
- Relative humidity: Max. 80%, non-condensing
- Net weight: 65 kg
- Maximum noise level: <70 dB
- Atmospheric pressure: 76 kPa / 106 kPa

Product intended for the European market – 220–240 V / 50 Hz power supply – European plug (type E/F)

Icanclave Autoclave: Maintenance and Error Message Guide

Components
- Distilled water tank
- LCD screen
- Control panel
- Main switch
- Key for draining distilled and used water
- USB port
- Internal printer (allows printing of sterilization cycle reports on thermal paper after the end of the cycle.)
- Safety valve
- Ventilation grille
- Locking system
- Power cable
- Label

Included Accessories
- Sterilizer
- USB
- 3 instrument trays
- Tray support
- Handle for tray removal
- Door adjustment tool
- 2 drain hoses
- Door guide
- Instruction manual

Regulations
- 93/42 / EEC Medical devices directive.
- 97/23 / EEC Pressure equipment directive.
- EN 13060 Small steam sterilizers.
- EN 61326, EN 61000 EMC.
- EN 61010-1, UL 61010-1 safety requirements.
- EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for processing medical materials.

Autoclave Process Step-by-Step
1. Open the door, take the tools and accessories located in the sterilization chamber, remove the packaging and clean them.

2. Connect the power cord to a suitable power source.

3. Connect the printer.

4. Power on: the main switch is located on the front, at the bottom right of the device. Once turned on, the LCD screen will light up and the basic operating symbols of the sterilizer, such as door position, water level, sterilization program, date, time, will light up.

5. Remove the top cover then fill the distilled water tank. If a beep sounds, it means you have exceeded the allowed water level in the tank. Empty the excess water until the alarm stops.

6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These must not be in contact. Check that all instruments are properly placed, so that water does not remain in hollow parts. Do not overload the instrument trays and do not place them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.

7. Select the sterilization program.

8. Start the sterilization cycle.
After selecting the sterilization program, place the instruments on the trays in the chamber using the provided plastic tongs.
Once the instruments are properly placed inside, close the door. Caution: make sure the door is properly closed, otherwise the sterilizer will not be able to operate.

9. Start the sterilization program.
Press the start button, the autoclave will begin to operate for about 30-75 minutes.

10. End of the sterilization cycle.
Once the sterilization cycle is complete, the printer will automatically print the full cycle report.
Once the pressure has returned to 0, you can open the door and remove the instruments. The autoclave will alert you with a beep once the sterilization cycle is complete.
Caution: Use the plastic tongs to remove the instruments.

IMPORTANT: Do not reuse the wastewater after draining the tank.

It is important to keep the packaging box in case of after-sales service

Program

Temp.

/Pressure

Sterilization time Total time (min)
8D Pro 12D Pro

18D Pro

23D Pro
QUICK 134 134℃/210Kpa 3.5 min 10-20 11-20 12-30 15-30
PACKAGED 134 134℃/210Kpa 4 min 25-40 28-45 30-49 38-57
PACKAGED 121 121℃/110Kpa 20 min 36-46 37-48 38-54 46-62
PRION 134 134℃/210Kpa 18 min 35-46 36-48 37-52 45-60
TEST B&D 134 3.5 min 10-20 15-25 15-30 28-35
TEST HELIX 134 3.5 min 10-20 15-25 15-30 28-35
EMPTY TEST – – 17-20 18-21 19-22 20-25

* The cycle duration is based on different loads and with/without preheating.

* The sterilization time and drying time can be adjusted.

Référence : 49.018

29 Liter Class B white autoclave with USB and integrated printer

In short
Class B 29 Litre White Autoclave with USB backup and integrated printer.Double hydraulic locking ...  Read more
Regular price
$4,449.00
Sale price
$4,449.00
Regular price
$6,844.00
Shipping calculated at checkout.
Black Week

Offre Black Week-2 395 €

Prix exceptionnel sur ce produit.

Toutes les offres →
Disponible immédiatement État du stock en temps réel dans notre entrepôt Le stock affiché peut varier légèrement, avec un délai de mise à jour pouvant aller jusqu'à 5 minutes. Ces informations sont données à titre indicatif et non contractuel.
Gagnez 4449 points en achetant ce produit
Secure Payment: Visa, MasterCard, Amex, Apple Pay
Free delivery on orders of €130 or more, including VAT
Delivery to your office, a pick-up point, or your home!
Garantie : 1 year
Mentions particulières : Photos non contractuelles

Discover these similar products