Treatment method using a fine jet of nitrous oxide under high pressure.
3 applicators included: - Ø 1-4mm: power ** - Ø 2-6mm: power **** - Ø 4-8mm: power ******
CryoPen guaranteed for 5 years and applicator for 2 years
The manufacturer undertakes to train you via a video call.
This device works to remove your patients' warts without any pain and comes as a replacement for Vercid, which is not always 100% effective. You can offer your patients a CryoPen package of 2 to 3 sessions with an interval of 7 to 10 days.
Positioning of the CryoPen instrument for treatment The instrument must be held vertically, with the tip pointing downwards. An angle of less than 45° should be avoided.
Effective application Before starting the treatment, take into account the age, location, size, and number of lesions, the skin type, the degree of tanning, and the season. The tip of the applicator (from where the liquefied N₂O comes) must be kept at a distance of 0.5 to 3 mm from the lesion. A distance greater than 5 mm between the lesion and the applicator tip will result in the N₂O liquid passing into a gaseous state, making it ineffective in terms of therapeutic results.
As you bring the flow closer to the lesion, you can observe the focal point of the jet on the tissue. The closer you get to the lesion, the greater the cryogenic power applied to the tissue. For smaller lesions and more delicate operations, we recommend increasing the distance. Control the amount of N₂O liquid to apply with quick back-and-forth movements of the applicator. Circular and crossed movements have an identical effect.
The condensation of moisture in the air can, in some cases, generate the formation of ice on the lesion. This "ice igloo" will hinder the effective operation of the liquid phase of the cryogen (at -89 °C) and must be removed. The learning curve for using the CryoPen is short. CryoPen allows you to have total control when applying the cryogen. Start by treating common lesions and, once you have gained experience, move on to more delicate lesions.
Duration/depth of treatment Hold the tip of the applicator as close as possible to the lesion. A typical freezing for viral lesions can take 5 to 10 seconds in the case of small flat warts and up to 45 seconds for plantar warts of maximum thickness. For most lesions, the treatment duration is between 2 and 30 seconds. This duration depends on the surface area and thickness of the treated tissue. To estimate the thickness, the practitioner must rely on their clinical experience. At the end of the first freezing cycle, let the tissue thaw for about 30 seconds, followed by a second cryogenics. Note that during this second cycle, the tissue will freeze faster than during the first cycle. This "freeze-thaw-freeze" technique offers the best chances of success. You will find this procedure in most scientific articles on cryotherapy. A follow-up visit is recommended after 2 to 4 weeks, to confirm the disappearance of all pathological tissue and to check whether or not follow-up treatment is necessary.
The user manual is available in the "attachments" tab above
Use of the instrument: Step 1: Loading a new cartridge The cartridges are packaged in peelable thermoformed blister packs with an assembled filter/perforator. The filters are used for the protection of the applicator, the perforator for piercing the cartridge. CryoPen X+ and CryoPen XP can be used with 16 g as well as 8 g N₂O cartridges, thanks to the 8/16 g converter. Check that the cavity contains no remaining elements. Open the peelable packaging. Remove the filter/perforator with the tweezers. Hold the end of the CryoPen pointing downwards. Place the filter/perforator in the instrument, ensuring that it is flat at the bottom of the loading cavity. The trocar of the perforator must point upwards! Take the cartridge and insert it into the cavity, narrow side down, above the filter/perforator.
Step 2: Perforation of the unused cartridge Gently screw the rear end of the CryoPen onto the front end. Proceed until you feel that contact is established between the filter/perforator block and the cartridge. Then position your hands so as to perform one last continuous rotation movement. Then turn with a quick motion until you reach the stop. You may hear a brief hiss. The briefer, the better!
Extraction of the used cartridge and emptying of the cavity Before loading a new cartridge, first release all residual gas from the cartridge by unscrewing the applicator and then pressing the trigger. Then unscrew the rear end. Throw away the used cartridge and filter/perforator. Regarding the CryoPen X+ and CryoPen XP instruments, be careful not to throw away the 16/8 g converter. Make sure that the used filter/perforator does not remain in the cavity. The cavity must no longer contain any elements.
Step 3: Use of your CryoPen Remove the applicator cap. Gently press the trigger to start the N₂O flow. Release the trigger to interrupt the flow of cryogenic liquid. 1 or 2 seconds after releasing the trigger, the gas remaining in the applicator is expelled. One cartridge can be used for several treatments and patients.
Important notes:
Make sure to use only the cartridges and filters/perforators provided by H&O Equipments nv/sa. Any other cartridge and any other filter/perforator will damage the instrument.
An incorrect positioning of the filter/perforator device in the loading cavity will cause irreversible damage to the instrument.
Residual foreign bodies present in the loading cavity during the insertion of a new filter/perforator can cause instrument failure.
The loaded instrument is under high pressure. Any modification made to the structure of the instrument can lead to a potential risk.
Never obstruct the gas expulsion opening with your hand, at the end of the rear part, when removing the cartridge!
Cartridges must be kept away from heat (max 50°C/122°F). Leave the applicator cap on when it is not in use.
CryoPen instruments are reserved exclusively for professional use.
N₂O cartridges contain both a liquid phase and a gaseous phase in equilibrium. The proportion of each of these phases depends on the ambient temperature and influences the output flow. The best performance is achieved when the cartridge temperature is between 19 °C and 22 °C. Lower or higher temperatures will give different pressure and density values of the cryogenic substance. Above 25 °C, the amount of liquefied N₂O in the CryoPen jet will decrease.
Empty cartridges must be thrown away with metal waste.
Description
CryoPen B+ for the treatment of plantar warts
Treatment method using a fine jet of nitrous oxide under high pressure.
3 applicators included: - Ø 1-4mm: power ** - Ø 2-6mm: power **** - Ø 4-8mm: power ******
CryoPen guaranteed for 5 years and applicator for 2 years
The manufacturer undertakes to train you via a video call.
This device works to remove your patients' warts without any pain and comes as a replacement for Vercid, which is not always 100% effective. You can offer your patients a CryoPen package of 2 to 3 sessions with an interval of 7 to 10 days.
Positioning of the CryoPen instrument for treatment The instrument must be held vertically, with the tip pointing downwards. An angle of less than 45° should be avoided.
Effective application Before starting the treatment, take into account the age, location, size, and number of lesions, the skin type, the degree of tanning, and the season. The tip of the applicator (from where the liquefied N₂O comes) must be kept at a distance of 0.5 to 3 mm from the lesion. A distance greater than 5 mm between the lesion and the applicator tip will result in the N₂O liquid passing into a gaseous state, making it ineffective in terms of therapeutic results.
As you bring the flow closer to the lesion, you can observe the focal point of the jet on the tissue. The closer you get to the lesion, the greater the cryogenic power applied to the tissue. For smaller lesions and more delicate operations, we recommend increasing the distance. Control the amount of N₂O liquid to apply with quick back-and-forth movements of the applicator. Circular and crossed movements have an identical effect.
The condensation of moisture in the air can, in some cases, generate the formation of ice on the lesion. This "ice igloo" will hinder the effective operation of the liquid phase of the cryogen (at -89 °C) and must be removed. The learning curve for using the CryoPen is short. CryoPen allows you to have total control when applying the cryogen. Start by treating common lesions and, once you have gained experience, move on to more delicate lesions.
Duration/depth of treatment Hold the tip of the applicator as close as possible to the lesion. A typical freezing for viral lesions can take 5 to 10 seconds in the case of small flat warts and up to 45 seconds for plantar warts of maximum thickness. For most lesions, the treatment duration is between 2 and 30 seconds. This duration depends on the surface area and thickness of the treated tissue. To estimate the thickness, the practitioner must rely on their clinical experience. At the end of the first freezing cycle, let the tissue thaw for about 30 seconds, followed by a second cryogenics. Note that during this second cycle, the tissue will freeze faster than during the first cycle. This "freeze-thaw-freeze" technique offers the best chances of success. You will find this procedure in most scientific articles on cryotherapy. A follow-up visit is recommended after 2 to 4 weeks, to confirm the disappearance of all pathological tissue and to check whether or not follow-up treatment is necessary.
The user manual is available in the "attachments" tab above
Use of the instrument: Step 1: Loading a new cartridge The cartridges are packaged in peelable thermoformed blister packs with an assembled filter/perforator. The filters are used for the protection of the applicator, the perforator for piercing the cartridge. CryoPen X+ and CryoPen XP can be used with 16 g as well as 8 g N₂O cartridges, thanks to the 8/16 g converter. Check that the cavity contains no remaining elements. Open the peelable packaging. Remove the filter/perforator with the tweezers. Hold the end of the CryoPen pointing downwards. Place the filter/perforator in the instrument, ensuring that it is flat at the bottom of the loading cavity. The trocar of the perforator must point upwards! Take the cartridge and insert it into the cavity, narrow side down, above the filter/perforator.
Step 2: Perforation of the unused cartridge Gently screw the rear end of the CryoPen onto the front end. Proceed until you feel that contact is established between the filter/perforator block and the cartridge. Then position your hands so as to perform one last continuous rotation movement. Then turn with a quick motion until you reach the stop. You may hear a brief hiss. The briefer, the better!
Extraction of the used cartridge and emptying of the cavity Before loading a new cartridge, first release all residual gas from the cartridge by unscrewing the applicator and then pressing the trigger. Then unscrew the rear end. Throw away the used cartridge and filter/perforator. Regarding the CryoPen X+ and CryoPen XP instruments, be careful not to throw away the 16/8 g converter. Make sure that the used filter/perforator does not remain in the cavity. The cavity must no longer contain any elements.
Step 3: Use of your CryoPen Remove the applicator cap. Gently press the trigger to start the N₂O flow. Release the trigger to interrupt the flow of cryogenic liquid. 1 or 2 seconds after releasing the trigger, the gas remaining in the applicator is expelled. One cartridge can be used for several treatments and patients.
Important notes:
Make sure to use only the cartridges and filters/perforators provided by H&O Equipments nv/sa. Any other cartridge and any other filter/perforator will damage the instrument.
An incorrect positioning of the filter/perforator device in the loading cavity will cause irreversible damage to the instrument.
Residual foreign bodies present in the loading cavity during the insertion of a new filter/perforator can cause instrument failure.
The loaded instrument is under high pressure. Any modification made to the structure of the instrument can lead to a potential risk.
Never obstruct the gas expulsion opening with your hand, at the end of the rear part, when removing the cartridge!
Cartridges must be kept away from heat (max 50°C/122°F). Leave the applicator cap on when it is not in use.
CryoPen instruments are reserved exclusively for professional use.
N₂O cartridges contain both a liquid phase and a gaseous phase in equilibrium. The proportion of each of these phases depends on the ambient temperature and influences the output flow. The best performance is achieved when the cartridge temperature is between 19 °C and 22 °C. Lower or higher temperatures will give different pressure and density values of the cryogenic substance. Above 25 °C, the amount of liquefied N₂O in the CryoPen jet will decrease.
Empty cartridges must be thrown away with metal waste.
The CryoPen B+ is designed to accommodate our largest cartridges: 23.5 g.This makes it ideal for ...
Read more
The CryoPen B+ is designed to accommodate our largest cartridges: 23.5 g. This makes it ideal for treating larger or deeper lesions and for infrequent use.
Calcul de la date de livraison…État du stock en temps réel dans notre entrepôt
Le stock affiché peut varier légèrement, avec un délai de mise à jour pouvant aller jusqu'à 5 minutes. Ces informations sont données à titre indicatif et non contractuel.